• Sts3-150 Three-Box Thermal Shock Test Chamber
  • Sts3-150 Three-Box Thermal Shock Test Chamber
  • Sts3-150 Three-Box Thermal Shock Test Chamber
  • Sts3-150 Three-Box Thermal Shock Test Chamber
  • Sts3-150 Three-Box Thermal Shock Test Chamber
  • Sts3-150 Three-Box Thermal Shock Test Chamber

Sts3-150 Three-Box Thermal Shock Test Chamber

Power Supply: 220V
Certification: CE, ISO
Inner Dimension: 600*500*500mm
Exterior Dimensions: Actual Products or Quotations Shall Prevail!
Temperature Fluctuation: ±0.5ºC
Time of Cradle Movement: Within 10s
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
STS3-150
Inner and Outer Box Materials
Steel Plate Paint or 304 Stainless Steel
Transport Package
Plywood
Specification
CE, ISO
Trademark
SINOWON
Origin
Dongguan, China
HS Code
9031809090
Production Capacity
100 Set/Week

Product Description

Three-box Thermal Shock Test Chamber
STS3 Series
Sts3-150 Three-Box Thermal Shock Test Chamber


Detail Display:
Sts3-150 Three-Box Thermal Shock Test Chamber


Cryogenic impact principle:
After the temperature of the cryogenic chamber is lowered to the set value through the refrigeration system, the cylinder damper of the cryogenic chamber is opened, and the circulating fan sends the low-temperature air into the test chamber, rapidly reducing the temperature of the test chamber to the set value, thus achieving low-temperature shock.

Thermal Impact Principle:
The air is heated by the heating wire, and the heat is sent to the test chamber by the circulating fan through the high-temperature box damper, causing the temperature of the test machine to rapidly rise to the set value, completing the high-temperature test.

Product Introduction:
The three-tank thermal shock test chamber is used to assess the ability of products (complete machines), components, parts, etc. to withstand sudden changes in temperature. This temperature shock test can understand the impact of temperature changes on the test sample once or multiple times.The main parameters affecting the temperature change test are the high and low temperature values of the temperature change range, the holding time of the sample at high and low temperatures, and the number of cycles of the test.It is generally used in a wide range of fields, from research and development to inspection and production.

Product Characteristic:
  1. The three-box structure uses pneumatic valves to switch the connection between the test area and the cold area, and between the test area and the hot area.  During testing, the air valves in the high-temperature and low-temperature areas are automatically opened, allowing for high- and low-temperature shock testing.  This shock method ensures that the product under test does not experience any mechanical shocks.
  2. Large touch screen controller, easy to operate, can set and display various operating data.
  3. No frosting function, sample temperature can be monitored.
  4. The cooling system uses a binary refrigeration system, which provides fast cooling and uses water cooling.
  5. It has an RS-232 communication interface device, which can be connected to a computer for control, editing, recording, and signal point status, making it easy to use.

Test Standard:
Meet the temperature shock test requirements of GB/T2423.22 (IEC60068-2-14), ISO16750, IPC-TM-650 and other series standards.

Specifications:
Commodity Three-box Thermal Shock Test Chamber
Model STS3-100 STS3-150 STS3-225
Code# 221-231 221-241 221-251
Interior Dimensions (W*H*D)mm 500*400*400 600*500*500 750*500*600
Exterior Dimensions(W*H*D)mm Actual products or quotations shall prevail!
Upper limit of preheating temperature 180ºC (non-standard can be customized to 200ºC)
Temperature rise time R.T→+200ºC≤40min
Lower limit of preheating temperature A (-10ºC~-55ºC);B (-10ºC~-65ºC);C (-10ºC~-80ºC) conditions are optional
Temperature Drop Time R.T→-80ºC≤90min
High temperature impact range 60~+150ºC (can be customized to 180ºC)
Low temperature impact range L (-10ºC~-40ºC);F (-10ºC~-55ºC);X (-10ºC~-65ºC) conditions are optional
Temperature Fluctuation ≤±0.5ºC
Temperature Deviation ≤±2ºC
Temperature Recovery Time ≤5min
Switching time of the damper High temperature tank ←→ low temperature tank steel within 3 seconds
Time of cradle movement Within 10S
Inner and outer box materials Steel plate painted or 304 stainless steel
Insulation Material High-temperature and low-temperature resistant high-density polyurethane foam insulation material
Refrigeration Method Air-cooled or water-cooled, using imported brand compressors
Safety Protection Device Leakage and short circuit protection, compressor high and low pressure protection, refrigerant high pressure protection, fault alarm system

Defrosts The Time
Sts3-150 Three-Box Thermal Shock Test Chamber
Three-box Impact Curve:
Linear temperature control (isothermal)
Sts3-150 Three-Box Thermal Shock Test Chamber




 
Sts3-150 Three-Box Thermal Shock Test ChamberSts3-150 Three-Box Thermal Shock Test ChamberSts3-150 Three-Box Thermal Shock Test Chamber
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now