Sinowon Automatic Macro Hardness Tester Vickers (ZHV-30A)

Type: Vickers Hardness Tester
Measuring Range: HV
Application: Metal
Standard: ISO, ASTM
Warranty: 1 Year
Mobility: Desktop
Customization:

Contact Supplier

Mr. Marshall Sinowon
Sales Director
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
ZHV-30A
Calibrating Method
Standard Hardness Test Blocks
Rated Voltage
AC220V/50Hz,AC110V/60Hz
Support Language
English
Customized
Non-Customized
Test Force
0.3kgf, 1kgf, 5kgf, 10kgf, 30kgf
Indentation Measurement
Software Measurement
Lens& Indenter Switch
Motorized Loading, Dwell and Unloading
Magnification of Microscope
Observation:10X; Measurement:20X
Digital Eyepiece
10X Digital Eyepiece
Auto X-Y Anvil
Size:110X110mm;Travel:25mm; Resolution:1um
Max. Height of Specimen
220mm
Instrument Throat
160mm
Packing Weight
80kg
Packing Dimension
500 X 490 X 700mm
Transport Package
Plywood Box
Specification
CE, ISO
Trademark
SINOWON
Origin
Dongguan/China
HS Code
90241020
Production Capacity
100 Sets/Month

Product Description

Automatic Macro Vickers Hardness Tester Vexus ZHV-30AZ/50AZ

Vexus ZHV-30/50AZ mainly equipped with precision force loading/unloading system, auto-turret, LCD display and panel, CCD adapter and camera, PC system, auto-platform and auto-controlling-measuring-software MV1000.

Vexus ZHV-30/50AZ has two-kinds of measuring model, one is by main instrument, it is traditional measurement operation; Another is by software.

By Vickers measuring software MV1000, all of the operation is by computer except for the focus-finding manually, which makes the operational step of hardness testing much easily and simply. Most of important, the auto-software

MV 1000 avoids the human-error and improves the accuracy of measurement.

Indenters
Sinowon Automatic Macro Hardness Tester Vickers (ZHV-30A)

Hardness Blocks
Sinowon Automatic Macro Hardness Tester Vickers (ZHV-30A)

Principle of Vickers Test
 

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.


Sinowon Automatic Macro Hardness Tester Vickers (ZHV-30A)
 
When the mean diagonal of the indentation has been determined the Vickers hardness may be calculated from the formula, but is more convenient to use conversion tables.
 
The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods.
 
The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.

 
Specifications:
Product Name Auto Macro Intelligent Vickers Hardness Tester
Model Vexus ZHV-30AZ Vexus ZHV-50AZ
Code# 821-213 821-223
Testing Force Kgf 0.3, 0.5, 1,3, 5, 10, 20,30 1, 2, 3, 5, 10, 20, 30, 50
N 2.94, 4.90, 9.80, 29.4,  9.80, 19.61, 49.0, 98.0, 
49.0, 98.0,196.1, 294.2 196.1, 294.2, 490.3
Indentation Measurement Digital Sensor /Software Measurement
Auto-turret Auto switch 10x, 20x lens & indenter
Loading Control Automatic (Loading, Dwell, Unloading)
Magnification of Microscope Observation:10x; Measurement:20x
Digital Eyepiece 10X Digital Eyepiece
Dwell Time Adjustable 0~99s
Auto Hardness Conversion HV convert to HRC and HB
Auto X-Y Anvil Size:110x110mm;Travel:25mm; Resolution:1um
Auto X/Y Anvil Movement Motorized by PC measuring software MV 100
Video System 1/3'' B/W CCD Camera; 1X CCD Adapter
Measuring Software MV 100
PC Communication P4: 2.4G, 80G Memory, USB interface and PCI slot,RS232 port
Max. Height of Specimen 220 mm
Instrument Throat 160mm
Illumination Adjustable LED 6V Cold light-source
Power Supply AC220V/50Hz;110V/60Hz
Dimension(LxWxH) 260×560×680mm
Packing Dimension 500x490x700mm
Gross/Net Weight 80Kg/55Kg
Execution Standard ISO 6507,ASTM E92,JIS Z2244,GB/T4340
Standard Delivery:
Standard Delivery Code# Standard Delivery Code# Standard Delivery Code#
Vickers Indenter 821-403 Auto Platform 821-703 1x CCD Adapter 821-363
HV 1 Hardness Block 821-603 Flat Precision Clamp 821-713 1/3'' CCD Camera 484-142
HV 10 Hardness Block 821-623 HP 17''LCD Monitor HP PC Power Cable/Accessories Box 821-803/821-903
10x Digital Eyepiece 821-303 Measuring Software MV 100 823-383 Anti-dust Cover 821-913
20X Objective 821-323 HP 17''LCD Monitor HP PC Instrument Manual Vexus ZHV-30AZ/50AZ
Optional Accessories:
Optional Accessories Code# Optional Accessories Code# Optional Accessories Code#
Unequal Specimen Clamp 821-743 Filament Clamp 821-763 Thin-Piece Clamp 821-753

Send your message to this supplier

*From:
*To:
avatar Mr. Marshall Sinowon
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Mr. Marshall Sinowon
Sales Director
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001