Customization: | Available |
---|---|
Type: | Ultrasonic Hardness Tester |
Measuring Range: | HV |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Commodity | Manual Ultrasonic Hardness Tester | ||||
Model | SU-300H | ||||
Code# | 882-141H | ||||
Optional Rrobe | Manual Probe:10N,20N,49N,98N ;Motorized Probe:3N,5N,8N,10N | ||||
Measuring Range (DIN) | HBS:100-500; HV:100-1500; HRC:20-68; HRB:55-100; HRA:37-85; Mpa: 255-2180N/mm | ||||
Measuring Accuracy(%) |
|||||
Scales | <250HV | 250~500HV | 500~800Hv | >800HV | |
HV0.1 | 6 | 7 | 8 | 9 | |
HV0.3 | 6 | 7 | 8 | 9 | |
HV0.8 | 5 | 5 | 6 | 7 | |
HV1 | 5 | 5 | 6 | 7 | |
HV5 | 5 | 5 | 5 | 5 | |
HV10 | 5 | 5 | 5 | 5 | |
Hardness Scales | Vickers(HV);Rockwell C(HRC); Rockwell A(HRA); RockwellB(HRB);Brinell(HB) | ||||
LCD | Color Screen | ||||
Data Display | Loading force,Testing-times, Testing result, Average, Maximum,Minimum,Deviation and Conversion scale. |
||||
Language | Chinese, English, German, Portugese, Turkish | ||||
Data Output | RS232 Hyper Terminal/Bluetooth Printer | ||||
Bluetooth | |||||
Data Storage | To save 1000-groups of measuring data and 20-groups of calibration data | ||||
Word Input | Letters and numerals | ||||
Working Environment | Temperature: -10°C to 50°C ; Humidity :30%-80% R.H. | ||||
Battery Voltage | Rechargeable lithium battery ; Voltage :4.2V, 4800mAh | ||||
Recharger Voltage | AC220V/50Hz, 110V/60Hz | ||||
Main unit Dimension and Weight | Main unit Dimension :160 x 80 x 30mm (L x W x H);Manual Probe:Φ22×153mm ; Weight(No Probe): 0.5Kg | ||||
Packing Dimension and Weight | Packing Dimension :320 x 430 x 155mm (L x W x H) ; Packing Weight (Standard Delivery):4.3Kg |
It must be known what material is tested, please check the typical application in the following table, it will be helpful to choose right probe. If there is coating or plating on the specimen, it is better to choose the motorzied probe with minimum testing force, but you must consider the roughenss of suface. If the roughness is high, the light force probe is not suitable.
If the speimen is small and massive, it is better to choose a stationary stand to make the testing reliably.
If the specimen is a cyliner-shape, it is better to fix the probe in a small/ large cylinder kit, or MU-200 portable stand, it will be benifical to get a credible testing result.
If the specimen can not be reached by the standard length probe, it is able to test it in the lengthen manual porbe or motorized probes. If it is inside wall of some turbines or pipes, it is able to use the manual shorten probe to complete the testing.