| Model | Maximum Permissible Error MPE(μm), L(mm), (ISO10360-2) | 3D Max. Speed (mm/s) | 3D Max. Acceleration (mm/s²) | |||
| MPEE | MPEP | |||||
| 20±2° | 20±5° | R0 | ||||
| Haquina 322 | 3.5+L/300 | 4.5+L/300 | 2.5 | 3.5 | 520 | 1730 |
| Haquina 454 | 3.5+L/300 | 4.5+L/300 | 2.7 | 4 | 520 | 1730 |
| Haquina 674 | 3.7+L/300 | 3.9+L/300 | 2.7 | 4 | 520 | 1730 |
| Model | Range of Travel(mm) | Dimensions(mm) | Daylights(mm) | Maximum weight of the measured workpiece (Kg) | Machine Weight (Kg) | ||||||
| X | Y | Z | Lx | Ly | Lz | Dx | Dz | Dz1 | |||
| Haquina 322 | 300 | 300 | 250 | 716 | 912 | 1750 | 300 | 114 | 364 | 100 | 350 |
| Haquina 454 | 400 | 470 | 358 | 917 | 1400 | 2230 | 560 | 121 | 541 | 160 | 758 |
| Haquina 674 | 600 | 700 | 358 | 1170 | 1811 | 2276 | 805 | 121 | 541 | 300 | 1148 |
| Probe configuration for performance testing: HH-MI: The probe is 21mm long,The tip diameter is 4 mm; HP-TM/TP20 Standard force measurement, The probe is 10mm long, The tip diameter is 4 mm. Performance metrics are valid under the following conditions: Standard ambient temperature: 18 - 22°C Ambient temperature changes : 1°C/h - 2°C/24h Temperature gradient: 1°C/m Relative humidity: 25% - 75% |
| Position Repeatiaility | 1.5µm |
| Increments | 15° |
| Angular Rotation | A=0°-90° B=±180° |
| Measuring Directions | ±X ±Y +Z |
| Adjustable trigger force | 0.1N-0.3N |
| Max. stylus length | 100mm |
| Position Repeatiaility | 1.5µm |
| Increments | 15° |
| Total number of Positions | 168 |
| Angular Rotation | A=0°-90° B=±180° |
| Maximum Extension Length | 50mm |
| Position Repeatiaility | 0.5µm |
| Increments | 7.5° |
| Total number of Positions | 720 |
| Angular Rotation | A=0°-105° B=±180° |
| Rotations Speed | 90° in 2s |
| Maximum Extension Length | 300mm |