Basic Info.

Model NO.
QTD-80C
Power Source
AC220V
Gross Weight
300kg
Packing Dimension
100 X 110 X 170cm
Transport Package
Plywood
Specification
CE, ISO
Trademark
SINOWON
Origin
Dongguan, China
HS Code
9031809090
Production Capacity
100 Set/Month

Product Description

Single-Temperature test chamber with wide range of temperature controls is mainly used to test performances of materials after in high temperature, low temperature or constant temperature.
It is one of the essential test equipments for aerospace, automotive, home appliances, scientific research department, etc.

Features:
1, Economical Single-Temperature controller also can accurately display the internal chamber temperature, but impossible for program testing for this controller.
2, Heating/Cooling System: Completely independent heating/cooling system can improve testing efficiency and using life.
3, Cycle System: Powerful blowing cycle system to avoid blind angle, makes temperature and humidity evenly distributed in the test area.
4, Viewing window and interior light makes viewing workspace freely and observe the test under best conditions.
5, Chamber exterior material is stainless steel with environmentally baking paint resists corrosion and provides impact resistance. Interior material is SUS304# stainless steel with excellent heat resistance and easy to clean.
6, Adjustable product shelf slides out for easier product access. Shelf design is non-tipping and supports large product loads.
7, Left side of chamber with diameter 50mm cable port for power-on test.

Single-Temperature Test Chamber QTD Series Conform Following Testing Standards:
1, IEC60068-3-5-2002 Environmental testing-Part 3-5 Support documentation and guidance-Confirmation of the performance of temperature chambers
2, IEC68-2-1 (GB-2423.1-2008) Testing A: Low temperature testing method
3, IEC68-2-2 (GB-2423.2-2008) Testing B: High temperature testing method
4, MIL-STD-202F (GJB360.8-87) High temperature life testing
5, MIL-STD-810D (GBJ150.3) High temperature method
6, MIL-STD810D (GBJ150.4) Low temperature method
7, IEC68-2-3 (GB2423.3-93) Testing Ca: Constant moist heat testing method
8, IEC68-2-30 (GB2423.4-93) Testing Db: Alternate moist heat testing method
9, MIL-STD-810D (GJB150.9-93) Moist heat testing method

Control Mode Balanced Temperature Control System
Operating Temp. & Humid. Range +5 deg ~ +35deg; <85%R.H.
Temp. Range A=0deg, B=-20deg, C=-40deg, D=-70deg ~ +100deg(150deg)
Temp. Fluctuation ±0.5deg
Temp. Uniformity ≤2.0deg
Temp. Resolution 0.01deg
Temp. Heating Time -40deg ~ +150deg within 35 min; -70deg ~ +150deg within 60 min
Temp. Cooling Time 20deg ~ -40deg within 60 min; 20deg ~ -70deg within 90 min
Power Supply AC380V, 50/60HZ, Three-phase (Specified by User)
Material Exterior Material Stainless steel with baking paint
Interior Material SUS304# Stainless steel
Insulation Material Rigid polyurethane foam
Refrigeration System Refrigerating Method Mechanical cascade refrigeration system
Compressor Air cooling hermetic compressor
Radiator Fin type radiator
Refrigerant Refrigerant R404A
Heating System Stainless steel radiating heater
Controller Single-Temperature Controller
Safety Devices Overheat protector Switch
Compressor overload protector switch
Fault alarm system
Accessories Viewing window, Chamber lamp, Cable port ø50mm,
Product shelf slides 2 pieces, universal casters
Single-Temperature Controller
Note: 1. The performance values are no specimen inside the test area
     2. At 20deg ambient temperature, rated voltage
     3. According to IEC68-2-1 and IEC68-2-2
     4. The above specifications are for reference only.
 
 
Chamber Dimensions:
 
Model Interior Dimension
W × H × D
Exterior Dimension
W × H × D
Interior Volume
QTD-80A/B/C/D 400 × 500 × 400mm
15.7" × 19.7" × 15.7"
930 × 1310 × 810mm
36.6" × 51.6" × 31.9"
80L
QTD-150A/B/C/D 500 × 600 × 500mm
19.7" × 23.6" × 19.7"
1030 × 1410 × 910mm
40.6" × 55.5" × 35.8"
150L
QTD-225A/B/C/D 500 × 750 × 600mm
19.7" × 29.5" × 23.6"
1080 × 1620 × 1120mm
42.5" × 63.8" × 44.1"
225L
QTD-416A/B/C/D 700 × 850 × 700mm
27.6" × 33.5" × 27.6"
1230 × 1660 × 1210mm
48.4" × 65.4" × 47.6"
416L
QTD-800A/B/C/D 1000 × 1000 × 800mm
39.4" ×39.4" × 31.5"
1530 ×1810 × 1310mm
60.2" × 71.3" × 51.6"
800L
QTD-1000A/B/C/D 1000 × 1000 × 1000mm
39.4" × 39.4" × 39.4"
1530 × 1810 × 1510mm
60.2" × 71.3" × 59.4"
1000L

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier