Good Price Digital Hardness Tester Vickers Meter China Supplier (HV-30AC)

Type: Vickers Hardness Tester
Measuring Range: HV
Application: Metal
Standard: ISO, ASTM
Execution Standard: ISO 6507,ASTM E92,JIS Z2244,GB/T4340
Loading Control: Automatic (Loading, Dwell, Unloading)
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
HV-30AC
Testing Range
8hv~2900hv
Illumination
Adjustable LED
Lens& Indenter Switch
Auto-Turret
Hardness Indication
1hv/ LCD Display
Test Force
0.3kgf, 0.5kgf, 1kgf, 2kgf, 2.5kgf,3kgf,5kgf,10kgf
Max Height of Specimen
160mm
Instrument Throat
135mm
Hardness Conversion
Hra, Hrb, HRC, Hv, HK, Hbw, etc
Transport Package
Carton
Specification
CE
Trademark
SINOWON
Origin
Guangdong, China
HS Code
9024102000
Production Capacity
20000

Product Description


Advanced Digital Macro Vickers Hardness Tester HV-30AC
 
HV-30AC Series is a half automatic and intelligent Vickers hardness testing machine, it adopts the close-loop force sensor to replace the traditional quality weight, this innovative design makes the instrument more accurate.
 
HV-30AC Series selection of testing force and dwell time is controlled and monitored on the front panel, it is automatic during the process of loading, dwell and unloading.  
 
HV-30AC Series adopts digital microscopes with adjustable LED illuminator, no need the operator to read the detail length of indentation, it only needs the operator to aim the D1, D2 diagonal of indentation and press the length key twice, then the built-in computer can computer the Vickers scale.

HV-30AC Series equipped with a large LCD screen, the operation is more directly and clearly.
 
HV-30AC Series doesn't need the operator to read the diagonal of indentation and check the Vickers testing table, it improves the testing  speed and accuracy of hardness testing obviously.
 
Vickers Video Measurement

XY Anvil
 
The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.


Principle of Vickers Test

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds. 

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation. 

When the mean diagonal of the indentation has been determined the Vickers hardness may be calculatedfrom the formula, but is more convenient to use conversion tables. 

The Vickers hardness should be reported like 800 HV/10, which means a Vickers hardness of 800, was obtained using a 10kgf force. Several different loading settings give practically identical hardness numbers on uniform material, which is much better than the arbitrary changing of scale with the other hardness testing methods. 

Specifications:
Product Name Advanced Auto-Turret Digital Vickers Hardness Tester
Model HV-10AC HV-30AC HV-50AC
Code# 821-171 821-181 821-191
Testing Force Kgf 0.3, 0.5, 1, 2,  0.5, 1, 2, 3,  1, 2,3, 5, 
2.5, 3, 5, 10 5, 10, 20, 30 10, 20, 30, 50
N 2.94, 4.9, 9.8, 19.6,  4.9, 9.8, 19.6, 29.4 9.8, 19.6, 29.4, 49.0, 
24.5, 29.4, 49.0, 98.0 49, 98, 196, 294 98.0, 196, 294, 490
Testing Range 8HV~2900HV
Lens& Indenter Switch Auto-turret
Loading Control Automatic (Loading, Dwell, Unloading)
Magnification of Microscope Observation:10x; Measurement:20x
Digital Eyepiece Magnification:10x
Dwell Time Adjustable 0~60s
Auto Hardness Conversion HRA\HRB\HRC\HV\HK\HBW\etc
Hardness Indication 1HV/ LCD Display
Output Data RS232/Mini-printer
Illumination Adjustable LED Illuminator
Max. Height of Specimen 160mm
Instrument Throat 135mm
Power Supply AC220V/50Hz;110V/60Hz
Dimension(LxWxH) 535 x225 x580mm
Packing Dimension 630 x460 x710mm
Gross/Net Weight 60Kg/50Kg
Execution Standard ISO 6507,ASTM E92,JIS Z2244,GB/T4340
Standard Delivery:
Standard Delivery Code# Standard Delivery Code# Standard Delivery Code#
Vickers Indenter 821-401 40x Objective 821-341 Accessories Box 821-901
10x Objective 821-311 Analogue X-Y Anvil 821-701 Anti-dust Cover 821-911
20x Objective 821-321 V-shape Anvil 821-521 Level Screw 821-931
10x Digital Eyepiece 821-301 Power Cable 821-801 Instrument Manual HV-10AC/30AC/50AC
Optional Accessories:
Optional Accessories Code# Optional Accessories Code# Optional Accessories Code#
25mm Digital Micrometer Head 821-719 Video Measuring Camera 821-811 USB Camera USB-V1 821-471
15x Digital Eyepiece 821-351 1.5x Vickers CCD Adapter 821-361 Vickers Measuring Software 821-461
LCD Video Monitor 821-821 V-Shape Anvil 821-521 Unequal Specimen Clamp 821-741