Auto Turret Vickers Hardness Testing Equipment

Type: Vickers Hardness Tester
Measuring Range: HV
Application: Metal
Standard: ISO, ASTM
Warranty: 2 Year
Mobility: Desktop
Customization:
Diamond Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
HV-50
Calibrating Method
Standard Hardness Test Blocks
Rated Voltage
110V/60Hz, 220V/50Hz
Support Language
English
Customized
Customized
Execution Standard
ISO 6507,ASTM E92,JIS Z2244,GB/T4340
Loading Control
Automatic (Loading, Dwell, Unloading)
Testing Range
8hv~2900hv
Illumination
Adjustable LED
Lens& Indenter Switch
Auto-Turret
Hardness Indication
LCD Touch-Screen Display
Test Force
1kgf, 2kgf, 2.5kgf,3kgf,5kgf,10kgf, 30kgf, 50kgf
Max Height of Specimen
150mm
Instrument Throat
125mm
Hardness Conversion
Hra, Hrb, HRC, Hv, HK, Hbw, etc
Transport Package
Carton
Specification
CE
Trademark
SINOWON
Origin
Guangdong, China
HS Code
9024102000
Production Capacity
20000

Product Description

1, Equips with Auto Turret, close loop loading system, key panel and touch screen double input methods, blue tooth transferring technology; Three models with max loading force at 10Kgf(Vicky HV10), 30Kgf( Vicky HV30) and 50Kgf(Vicky HV50), meets different kinds of materials measuring requirement.
2, Close loop loading system is to realize auto loading, dwell and unloading, makes better accuracy and easier installation.
3, 5.2" color touch screen with innovative interface design, makes force selection, dwell time setting, scale conversion and data reading, transferring, printing more convenient and fast.
4, Operator can smoothly switch objectives and indenter by auto turret, maximally avoid damages of objectives, indenter and force system by manually operation.
5, One touch operation of diagonal line by high resolution measurement/observation objectives and built-in length encoder high definition digital eyepiece.
6, Auto hardness conversion from vickers scale HV to HK, HBW, HRA, HRB, HRC, superficial rockwell scales, etc.
7, Equips with Bluetooth Device, optional Bluetooth printer and computer acceptor is available to realize wireless printing and data transferring.
8, Abundant optional auxiliary devices to make hardness measurement more automated and eliminate human operation error. MV series vickers software is recommended, includes USB camera, C mount adapter and computer.

Application Range:
1, Testing very thin materials like foils, thin pieces, coatings layers, etc;
2, Measuring hardness of the surface of a part, small parts or small areas;
3, Measuring individual micro-structures;
4, Measuring the depth of case hardening by sectioning a part and making a series of indentations to describe a profile of the change in hardness.


The advantages of the Vickers hardness test are that extremely accurate readings can be taken, and just one type of indenter is used for all types of metals and surface treatments. Although thoroughly adaptable and very precise for testing the softest and hardest of materials, under varying loads, the Vickers machine is a floor standing unit that is more expensive than the Brinell or Rockwell machines.


Principle of Vickers Test

The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.

The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.

When the mean diagonal of the indentation has been determined the Vickers hardness may be calculatedfrom the formula, but is more convenient to use conversion tables.


When selecting a hardness tester for your application, it is important for you to consider the following:

1, What kind of hardness scale to be used?
2, What is the material to be tested, and is this material suitable to the type of test method you are considering?
3, How large is the part, component or specimen to be tested?
4, Is the test point difficult to reach?
5, What is the quantity of testing that will be done?
6, How accurate does your test result need to be?
7, What is your budget?
8, What is the required return on investment and do you have ways to measure reductions in costs- yields, throughput, operator efficiency?
9, What testing problems have you experienced in your current method?
10, How knowledgeable are the users of the tester?
Name Color Touch Screen Digital Vickers Hardness Tester
Model Vicky HV10 Vicky HV30 Vicky HV50
Code# 821-240 821-260 821-280
Loading Force 2.94N(0.3Kg) 4.9N(0.5Kg) 9.8N(1Kg)
4.9N(0.5Kg) 9.8N(1Kg) 19.6N(2Kg)
9.8N(1Kg) 19.6N(2Kg) 29.4N(3Kg)
19.6N(2Kg) 29.4N(3Kg) 49.0N(5Kg)
24.5N(2.5Kg) 49.0N(5Kg) 98.0N(10Kg)
29.4N(3Kg) 98.0N(10Kg) 196N(20Kg)
49.0N(5Kg) 196N(20Kg) 294N(30Kg)
98.0N(10Kg) 294N(30Kg) 490N(50Kg)
Lens & Indenter Switch Auto Turret
Data Transfer Support Bluetooth Printing
Hardness Resolution 1HV
Measuring Range 8HV~2967HV
Loading Control Auto Loading, Dwell and Unloading
Magnification of Objective Observation: 10x/40x; Measurement: 10x/40x
Hardness Conversion HRC, HV, HBS, HBW, HK, HRA, HRD, HR15N, HR30N
HR45N, HS, HRF, HR15T, HR30T, HR45T, HRB
Eyepiece 10x Digital Eyepiece
Dwell Time Adjustable 1~60s
Display 5.2" Touch Screen, Resolution 640*480
Conversion Standard ASTM, DIN
Languages Chinese, English
Illumination Adjustable halogen lamp (Optional LED Illumination)
Max height of Specimen 150mm
Throat 125mm
Power supply AC220V/50Hz; AC110V/60Hz
Dimension 535*190*585mm
Packing Dimension 610*450*770mm
Gross/Net Weight 47kg/43kg
Executive Standard ASTM E92, ISO6507, GB/T4340, JIS Z2245
Standard Delivery
Name Code# Name Code# Name Code#
Vickers Indenter 821-401 X-Y Anvil 821-701 Power Cable 821-801
10x Objective 821-311 40x Objective 821-341 Accessory Case 821-901
10x Digital Eyepiece 821-301 Hardness Block HV1 821-601 Level Screw 821-931
Hardness Block HV10 821-621 Quality Certificate Vicky HV10/30/50 Operation Manual 1 Copy
Optional Accessories:
Optional Accessories Code# Optional Accessories Code# Optional Accessories Code#
25mm Digital Micrometer Head 821-719 Video Measuring Camera 821-811 USB Camera 821-471
15x Digital Eyepiece 821-351 1.5x Vickers CCD Adapter 821-361 Vickers Software 821-461
LCD Video Monitor 821-821 V-Shape Anvil 821-521 Unequal Specimen Clamp 821-741

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now